pH BOSS Instructions Handbook
Table of Contents
INTRODUCTION
PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS CAREFULLY AND NOTE HOW THEY APPLY TO YOUR PARTICULAR POOL AND EQUIPMENT.
IMPORTANT: ALWAYS USE DILUTED ACID. SEE SAFETY & WARRANTY SECTIONS.
IMPORTANT: ALWAYS USE THE BUFFER DELAY FUNCTION WHEN ADDING BUFFER (ALKALINITY INCREASER / SODIUM BICARBONATE). THIS WILL REDUCE THE CONSUMPTION OF BOTH ACID AND BUFFER. SEE PAGE 11.
pH level is one of the most important pool balance parameters for any type of pool.
Whether the pool is ionized, ozone, salt water chlorinated (including salt chlorinators that use alternative salts such as magnesium and potassium), liquid chlorine etc, the pH must be maintained at the correct level for optimum water quality and algae control.
The pH BOSS takes the hassle out of controlling pH, by doing the job for you. Whenever the pool filtration pump is running, the pH BOSS will add small, frequent doses of diluted hydrochloric acid to ensure correct pH at all times.
This not only saves you time, but it also takes the guesswork out of colour matching with pH tests and reduces chemical usage. In particular, the small doses will not reduce total alkalinity as quickly as adding a larger amount of undiluted acid every week or two.
So the pH BOSS saves you time, frustration AND money !
Before installing the pH BOSS, the pool water should be correctly balanced, particularly total alkalinity. The pH BOSS can be safely used on brand new pools, including those pools which have high acid demand for the first few weeks, months and years of operation.
Take note of the few “do’s and don’ts” and you will have a simple and trouble free start up.
Bionizer is committed to creating a more healthy environment… the pH BOSS is one integral component of our ongoing journey in this direction.
Other components to advance ourselves along the path back to a toxic free world include the original Bionizer Bio-effective ionic pool and spa purifer, and also the Eco-Oxidizer chemical free pool oxidizer.
Now for the first time pools are able to stay healthy and clear without any toxic substances polluting your swimming environment or your lifestyle. You are removed from all but the most simple tasks required for pool care.
If you use a pool care service you can reduce the time they visit… they are now almost redundant. Let them visit once a month and sweep the pool, check the skimmer and add some acid to the pH reservoir and you do no pool care whatsoever.
This is the Bionizer “Ultimate Solution” to Pool Care… and your commitment to help us all return to a toxic free Planet for your children to enjoy.
pH BOSS DISPLAY
The LCD in your pH BOSS provides all the information you need to help ensure that the unit is maintaining the pH of your pool accurately, and that you know when it is time to carry out basic maintenance. Additionally, the pH BOSS will warn you when it detects if something is not working as it should. This page is a summary of the information that your pH BOSS may display at various times.
Alarm and Reminder Messages
When the pH reading has been outside the Set Point for 4 hours, the display alternates between the alarm screen, and “Alrm” in the status, and the beeper sounds. See page 12 for how to reset the alarm and rectify the cause.
When the peristaltic dosing pump has operated for a total of 50 hours, the pH BOSS will show the squeeze tube reminder.
See page 15 for instructions on how to lubricate or change the Squeeze Tube.
Tube Age displays how many hours the peristaltic dosing pump has pumped acid or base with the current squeeze tube.
Cal Age is the number of days since the last successful pH probe calibration.
The pH BOSS will show the pH Probe calibration reminder, 6 months after the last successful calibration.
CAUTIONS & WARNINGS
IMPORTANT:
It is important to follow basic safety precautions when installing and using this electrical equipment, including the following :
- Ensure you read and follow all instructions.
- WARNING – ALWAYS USE DILUTED ACID AT A RATIO OF NOT LESS THAN 4 PARTS WATER TO 1 PART ACID.
- WARNING – Do not allow children to use this product unless they are closely supervised at all times. This is to prevent accidental injury.
- Keep all cables and tubes visible and do not bury them. Also, position them so that they do not get damaged by lawn mowers, hedge trimmers and other equipment.
- WARNING – To prevent electrical shock, acid spillage or incorrect dosing, replace damaged cords or tubes immediately.
- Read these instructions and keep the instruction manual in a safe place.
IMPORTANT:
It is important to follow basic safety precautions when installing and using this electrical equipment, including the following :
- Ensure you read and follow all instructions.
- WARNING – ALWAYS USE DILUTED ACID AT A RATIO OF NOT LESS THAN 4 PARTS WATER TO 1 PART ACID.
- WARNING – Do not allow children to use this product unless they are closely supervised at all times. This is to prevent accidental injury.
- Keep all cables and tubes visible and do not bury them. Also, position them so that they do not get damaged by lawn mowers, hedge trimmers and other equipment.
- WARNING – To prevent electrical shock, acid spillage or incorrect dosing, replace damaged cords or tubes immediately.
- Read these instructions and keep the instruction manual in a safe place.
ACID SAFETY
PLEASE FOLLOW THESE IMPORTANT ACID SAFETY INSTRUCTIONS.
ALWAYS ADD THE ACID TO WATER ALREADY IN THE DRUM, NEVER WATER TO ACID.
For pools of 30,000L (8,000 Ga) and under, dilute 8 parts water to 1 part acid. So add 2 Litres of acid for the 20 Litre drum in the example above.
1. WARNING – always use diluted acid at 1 part acid to 4 or more parts water.
2. ALWAYS add acid to a larger volume of water. NEVER add water to acid.
3. ALWAYS wear safety glasses and gloves.
4. ALWAYS dilute acid in a well ventilated area, preferably outdoors.
5. ALWAYS have a source of fresh water nearby, such as a hose, so you can wash down accidental spillages.
6. ALWAYS ensure that the acid drum is BELOW the level of the pH BOSS Tee, to ensure that the acid cannot syphon from the drum to the pool.
7. In case of acid spillage onto clothing, eyes, skin, concrete etc, wash down with large amounts of fresh water immediately. SEEK MEDICAL ADVICE IF NECESSARY.
pH BOSS INSTALLATION
READ THE DO’S AND DON’TS AND TAKE THE TIME TO INSTALL CORRECTLY.
The pH BOSS can be installed onto a new pool or an existing pool with minimal pool preparation. Ensure that the pool is correctly balanced, in particular the Total Alkalinity.
- Installing your pH BOSS takes around 30 minutes.
NOTE: Turn off all valves prior to fitting the T-piece (avoid leaks), and turn them back on again before switching pool pump back on.
2. Alternatively engage a competent person to do the job.
3.If installing it yourself you will need :
- PVC pressure glue and primer
- A fine tooth saw.
4. The Probe/Injection Tee must be fitted on the pipe that sends water back to the pool after it has been filtered (the “Return Line”).
- If a Bionizer and/or Eco-Oxidizer is installed, fit the pH BOSS tee BEFORE the Eco-Oxidizer and Bionizer Ionizing Pods.
- If a Salt Chlorinator is installed, fit the pH BOSS tee BEFORE the Salt Chlorinator cell. The acid will help to keep the expensive Chlorinator cells clean.
If a liquid Chlorine injection system is fitted, install the tee BEFORE the Chlorine injection point. The acid will help prevent the Chlorine injector becoming clogged with calcium.
TEE PIECE INSTALLATION
- For 50mm (2″) pipe, cut out a 6cm (2.5″) section of pipe sufficient for the Probe/Injection Tee piece. For 40mm (1.5″) pipe, where the reducing bushes will be used, cut out a 7cm (2.75″) section of pipe.
- If the Tee piece diameter is larger than the pipe then use the 50mm to 40mm reducing bushes provided by glueing them in place in the Tee piece before fitting. The pipe should now fit snugly into the Tee piece.
- Be sure to install the Tee piece in the correct direction of the water flow, as per the arrow on the Tee. The Tee piece should be installed so that the pH Probe is within 30ºof vertical. (See page 8).
pH PROBE ORIENTATION
When installing the pH BOSS Tee, it is critical that the probe be within 30º from vertical.
DO NOT FIT THE TEE TO A VERTICAL PIPE, AS THIS WILL MAKE THE PROBE HORIZONTAL, WHICH WILL RENDER THE pH PROBE INOPERABLE.
CONTROL BOX INSTALLATION
The control box MUST be mounted vertically, with the cables at the bottom, in order to be weather resistant. Any water ingress due to the unit being incorrectly mounted is not covered by warranty.
- Choose a position that will allow you to see the pH BOSS Display easily. Fix the control box in position using screws at each corner of the box.
NOTE: Make sure that the pH BOSS is positioned near enough to a power outlet and to the T -piece and acid drum to allow the power connecting and sensor cables to reach without straining.
2. Make sure that the unit is undercover and that the Display is not in direct sunlight as it is not covered by warranty if it is damaged by sunlight.
TEE PIECE HOSE INSTALLATION
Remove the nut from the one way valve fitting on the Tee piece.
Slip the Nut over the hose.
Push the hose firmly onto the tube fitting.
Tighten the nut over the hose. Tighten firmly with fingers. DO NOT USE A TOOL.
DRUM WEIGHT HOSE INSTALLATION
- Remove the lid from the acid drum that you will use.
Drill a 7.0mm or 1/4 inch hole into the top of the drum lid.
Push the end of the drum weight hose through the drum lid.
Fit the hose onto the drum weight tube fitting in the same way as described in the Tee Piece Hose Installation section above and illustration below.
pH PROBE INSTALLATION
Fit Teflon tape onto the thread of the pH Probe. Carefully remove the protective cap from the tip of the probe.
Screw the pH Probe into the Tee piece thread. Tighten firmly by hand. DO NOT OVER-TIGHTEN. DO NOT USE A TOOL.
After the pH Probe is installed in the Tee piece, connect plug on the pH Probe cable into the probe socket on the pH BOSS. Push the plug into place and 1/4 turn clockwise to lock it into place. See the BNC pH Probe socket diagram, Page 4.
AFTER ALL HOSE FITTINGS ARE COMPLETED, AND THE PROBE IS FITTED, TEST THE SYSTEM WITH FRESH WATER, USING THE MANUAL DOSE FUNCTION (PAGE 12). CHECK CAREFULLY FOR ANY LEAKS AND CORRECT AS NEEDED.
pH BOSS SETTINGS
- Press the PROGRAM / SET button to move through each of the six user settings.
- If no button has been pressed for 30 seconds, the unit will return to the normal readout display. Any changes will not be saved.
- Use the ⬇ and ⬆ keys to change settings.
- When changing a setting, press PROGRAM / SET after the desired setting is programmed to save the changes and return to the normal readout display.
- To quit any screen without saving changes, press AUTO / OFF to cancel
AUTO / OFF BUTTON
Press to select Auto, Off or Buffer Delay:
AUTO: Unit will add acid when pH is outside the set point.
Buffer Delay: This function will stop the unit dosing acid for 24 hours.
ALWAYS USE THIS SETTING AFTER ADDING BUFFER (ALKALINITY INCREASER / SODIUM BICARBONATE) TO THE POOL, TO REDUCE THE AMOUNT OF ACID AND BUFFER USED.
OFF: Unit will not dose any acid again until this setting is changed.
AUTO / OFF is also the “CANCEL” button to exit without saving changes of settings.
DOSE SETTING
This range of this setting is 2 to 25 minutes.
- Press ⬇ and ⬆ to enter setting 2 to 25.
- Press PROGRAM/SET save the new setting.
- Alternatively, press AUTO/OFF to cancel without saving.
The dose setting is used to set the acid pump addition and waiting times, and are related to how quickly the pool turns over the water. This is related to pool size, and pump/pipe setup. In general, a smaller pool would use a lower Dose Setting than a large pool. However other factors can affect this, such as pool turnover time.
As a guide, use the following setting as a STARTING point when the unit is first installed :
2 …..Up to 30,000 L / 8,000 Ga
5 …..30,000 to 75,000 L / 8,000 to 20,000 Ga
10 …75,000 to 150,000 L / 20,000 to 40,000 Ga
15 …150,000 to 250,000 L / 40,000 to 65,000 Ga
20 …250,000 to 500,000 L / 65,000 to 130,000 Ga
25 …>500,000 L / 130,000 Ga
For pools under 30,000 L (8,000 Gallons), be sure to dilute the acid at 8 parts water to 1 part acid (page 6).
If the pH BOSS does not keep up with acid demand, and the Alarm sounds, increase the dose setting by one step and check in 2 days.
If the alarm is tripped due to low pH, reduce the dose setting by one step and check in 2 days.
DOSE SETTING FOR NEW POOLS
New concrete/pebblecrete, marblesheen and quartzon pools can have very high pH level for the first 1 to 3 months of operation. Readings of pH10 or even higher are possible. Even when the pH is brought down to the correct pH7.5, the pH reading will drift back up over the following hours or days.
The acid demand during the initial period could be as high as 1 Litre (1 Quart) of acid per 10,000L (2,500Ga) of pool water per day. This acid demand will gradually reduce over the first 1 to 3 months.
If the pH BOSS is not able to maintain pH at the pH7.5 set point, please increase the Dose Rate setting to a higher value. This will add more acid in each dosing cycle, and therefore be able to control the pH during this high acid demand period of time.
MANUAL DOSE
The range of this setting is from 0 to 5 Litres. Use this function to add a measured dose of diluted acid.
- Use the ⬇ and ⬆ buttons to enter 1 to 5 Litres.
- Press PROGRAM / SET to start pumping.
- Please note that the litres are the total litres of liquid being pumped, and does not take into account the dilution ratio of the acid. 1 Litre equals 200mL of acid when the acid is diluted 1 part acid to 4 parts water. Take care to not overdose the pool the acid.
CHANGING THE pH SET POINT
- Use the Use the ⬇ and ⬆ buttons to enter a new Set Point value.
- Press PROGRAM / SET to save.
- Alternatively, press AUTO / OFF to quit without saving changes.
Please note that the pH BOSS factory preset default Set Point is pH7.5. This is most likely to be the best setting for your pool, so changing the Set Point is only recommended for experienced users.
ALARM FUNCTION
When the Alarm is set to ON, the beeper will sound the acid pump will be disabled if the pH exceeds the set point for more than 4 hours.
When the Alarm is set to OFF, the alarm will never be triggered, regardless of the pH reading. Only advanced users should set the alarm to OFF, and only temporarily while the cause of the alarm beeping is being rectified.
Use PROGRAM / SET to select Alarm.
- Press ⬇ and ⬆ to select On or Off.
- Press PROGRAM / SET to save.
- Press AUTO / OFF to quit without saving.
When the alarm has been triggered, the pH BOSS will sound the beeper and also display will alternative between an alarm screen and “Alrm” in the status area:
THE ACID PUMP WILL BE DISABLED AND THE pH BOSS WILL NOT PUMP MORE ACID UNTIL THE ALARM HAS BEEN RESET.
You must press AUTO / OFF to reset the alarm and return to normal operation.
The reason for the alarm being triggered should be found and rectified too. It could be due to any of the following:
Problem: High acid demand in new concrete, marblesheen or quartzon pool.
Fix: Increase the Dose Setting to a higher value (page 11) and set the Alarm function to OFF for the first 2 to 3 months until the acid demand settles to normal amounts.
Problem: Acid drum is empty.
Fix: Make up a new drum of diluted acid. Dilution ratio should be at least 4 parts water to 1 part acid. See page 6.
Problem: Dose Setting is too low or too high.
Fix: See page 11 for information on how to change the Dose Setting.
Problem: pH Reading is incorrect
Fix: Re-calibrate the pH Probe. See page 13.
Problem: pH Probe is broken or faulty.
Fix: If re-calibration is not possible, then replace the pH Probe. A replacement pH Probe can be ordered online here.
Problem: Pump is not pumping acid correctly.
Fix: Check all tube and hose fittings for leakage. Re-fit or replace as needed. Check squeeze tube inside pump for leakage and replace if necessary. See page 15. A replacement Squeeze Tube can be ordered online here.
pH PROBE CALIBRATION
A LITTLE PREVENTATIVE MAINTENANCE WILL HELP YOU GET THE MOST FROM YOUR pH BOSS.
The pH BOSS will display a reminder to calibrate the pH Probe approximately every 12 months:
The pH Probe should be calibrated to ensure that the readout is correct. Calibration is simply the process of placing the pH Probe into a solution of known pH, and adjusting the readout to that value.
The pH BOSS can be calibrated in one of two ways:
- Inline Calibration: This is done by obtaining an accurate pH measurement of the pool water and adjusting the readout to that value.
- pH7.0 Buffer Calibration: This involves removing the pH probe from the tee piece, placing it into a pH7.0 Buffer solution, and adjusting the readout to 7.0.
INLINE CALIBRATION
1. Measure the pH of the Pool
Set the pH BOSS to Buffer Delay or OFF mode an hour or more before measuring the pH of the pool. Do not change back to Auto mode until after pH calibration is completed. See page 11.
Ensure that the pool filtration pump has been running and no acid has been added for at least 1 hour prior to doing an Inline Calibration. This is to ensure that the pH level is stable throughout the whole pool.
Measure the pH of the pool with a good quality, calibrated pH meter. Alternatively, take a sample of pool water to a pool shop which has an electronic pool balance measurement system. A standard pool pH test kit is NOT accurate enough to be relied upon for pH calibration.
2. Calibration Procedure
- The pH BOSS should already be switched on, and the pool pump running as per step 1.
Press the PROGRAM / SET button until the pH Calibration screen is displayed, as per the example below. The “Current” reading may be 7.5 or another value, depending on the condition of the pH Probe and current pH of the pool water.
- Adjust the “Cal pH” value to the pH of the pool, as measured in step 1. The flashing “X”, indicates that the reading is not yet stable. DO NOT calibrate until the “X” changes to a “✔”.
- When the reading is stable and the “✔” is displayed, press PROGRAM / SET to calibrate the pH BOSS.
- Set the pH BOSS back to Auto mode. See page 11.
CALIBRATION FAILURE
If pH calibration fails, the pH BOSS will display this message:
Clean the pH probe as per the troubleshooting section on page 17, then retry calibration.
If the calibration failure persists, the pH probe will most likely need to be replaced. This can be purchased online here.
pH7.0 BUFFER CALIBRATION
1. Prepare the pH BOSS for Calibration
- Ensure that the pool pump is switched off and unplugged during the entire calibration procedure.
- Connect the pH BOSS to a power outlet socket, but do not switch on yet.
2. Prepare pH7.0 Calibration Buffer
- Empty the entire contents of salt crystals inside the pH7.0 Sachet into the calibration jar (see picture below).
- Fill the Buffer Jar to the 250ml mark with distilled water. Filtered tap water can also be used.
- Replace both the seal and the lid, then shake well for 1 minute to ensure that the salts are fully dissolved.
3. Remove the pH Probe from the Tee
- Unplug the pH Probe from the pH BOSS first. (This will avoid the cable getting twisted when the pH Probe is unscrewed.) Unscrew the probe completely from the Tee.
- Reconnect the pH Probe to the pH BOSS.
- Rinse the probe well in clean water. De-ionized or distilled water is ideal, but tap water will suffice.
4. Place pH Probe into pH7.0 Buffer
Place the pH Probe into pH7.0 Buffer, immersing to a depth of at least 25mm, to the threaded section of the main body.
5. Calibration Procedure
Switch the pH BOSS power on.
Press the PROGRAM / SET button twice to bypass the start-up screen delay.
Press the PROGRAM / SET button until the pH Calibration screen is displayed, as per the example below. The “Current” reading may be 7.0 or another value, depending on the condition of the pH Probe and current calibration setting.
- Adjust the “Cal pH” value to exactly 7.0. The flashing “X”, indicates that the reading is not yet stable. DO NOT calibrate until the “X” changes to a “✔”.
When the reading is stable and the “✔” is displayed, press PROGRAM / SET to calibrate.
6. Re-fit pH Probe and Power Connections
Disconnect the pH Probe from pH BOSS (to prevent twisting the cable) and re-fit into the Tee. Re-connect the pH Probe to pH BOSS when done.
Re-connect the pH BOSS and pool pump to the sanitiser controller’s pool pump outlet.
Switch your pool equipment back on.
CALIBRATION FAILURE
If pH calibration fails, the pH BOSS will display this message:
Clean the pH probe as per the troubleshooting section on page 17, then retry calibration.
If the calibration failure persists, the pH probe will most likely need to be replaced. This can be purchased online here.
MAINTENANCE
PUMP SQUEEZE TUBE LUBRICATION AND REPLACEMENT
The pH BOSS monitors the running time of thedosing pump and will display a reminder to replace the squeeze tube when this time exceeds 50 hours.
At this time, the peristaltic pump squeeze tube either needs to be lubricated or replaced as per the instructions below.
- Switch off the pH BOSS and ensure that the pool pump is also off.
- Remove and inspect the squeeze tube. If it is round and not flattened, and shows no visible signs of wear, then it can simply be lubricated as per the instructions in this section.
- If the squeeze tube appears a flattened and has wear marks, then it should be replaced. Replacement tubes can be purchased online here.
- Damage caused by acid leaking from a broken squeeze tube is not covered by the warranty, so it is your responsibility to check and replace it as necessary.
REMOVING THE SQUEEZE TUBE
Hold the top and bottom of the pump cover.
Lift up the pump cover from the bottom side.
3. Pull off the pump cover.
4. Remove the Squeeze tube. The rotor may come out, but can be pushed back in place.
Lubricating the Squeeze Tube
(Skip this step when replacing squeeze tube, as these are supplied pre-lubricated.)
Apply a THIN SMEAR of Silicon grease to the squeeze tube and rotor shaft as shown above.
DO NOT over-lubricate, as this will attract dirt and grit, which will cause premature wear of the squeeze tube and rollers.
WARNING: Use only silicon grease. Petroleum gel and other oil-based lubricants may cause the squeeze tube to break down, resulting in corrosive diluted acid spillage.
Refitting the Squeeze Tube
- Pull out the pump rotor a little, and place the squeeze tube between the pump body and the two rollers.
- Push the squeeze tube and rotor into the pump body. Ensure that the inlet and outlet are seated in the guides on each side of the pump body.
Refitting the Pump Cover
- Re-fit the pump cover until it clips into place. There should be no gaps anywhere between the pump body and cover. Ensure that the squeeze tube is not pinched on either side.
Fitting New Supply and Delivery Tubes
Replacement Squeeze Tubes are supplied with new Supply and Delivery tubes pre-fitted for your convenience. It will be necessary to connect these to the drum weight and to the one-way valve in the Tee piece.
See page 10 for full instructions on making these tube connections.
Resetting the Squeeze Tube Reminder
Once the Squeeze Tube has been either lubricated or replaced, the last step is to reset the Squeeze Tube reminder to zero.
- Press the PROGRAM / SET button until the Tube Change screen is displayed, as per the example below. The Tube Hours reading is the total number of hours that the dosing pump has actually been running.
Press ⬆ button to select “Yes”. Press PROGRAM / SET to reset the Tube Hours back to zero.
TROUBLESHOOTING
CHECK THIS SECTION BEFORE CALLING OR SENDING YOUR pH BOSS FOR SERVICE.
Unstable or inaccurate pH readings
pH Probe is dirty.
- Disconnect probe BNC connector from the pH BOSS, then unscrew probe from the pipe.
- Wipe the glass bulb with a soft tissue soaked with methylated spirits.
- Soak the tip of the probe in diluted Hydrochloric acid (for example, from your pH BOSS diluted acid drum).
- Rinse the pH Probe thoroughly in clean water.
- Screw probe back into pipe and re-connect probe BNC connector.
pH Probe needs to be re-calibrated.
Pool water is very pure and has low conductivity.
- Add one bag of pool salt per 50,000 Litres (13,000 Ga) of pool water.
pH reading cannot be calibrated
pH Probe is dirty.
Follow the pH Probe cleaning procedure above.
pH Probe is faulty.
Replace pH Probe. Please contact your distributor or Bionizer.
pH reads around pH7 without changing
Short circuit in pH Probe BNC Plug or Socket.
Disconnect pH Probe plug from socket. Dry out with a hair dryer or allow to air dry. Reconnect and re-check.
If problem persists, return pH Probe to have connector replaced, or replace the pH probe. Please contact your distributor or Bionizer.
pH reads around pH4 to 5 without changing
Glass bulb or internal stem of pH Probe is cracked.
Replace pH Probe. Please contact your distributor or Bionizer.
Unit does not power up
Faulty pH BOSS unit.
Faulty pH BOSS main unit. Return to Bionizer for repair.
Unit is not adding acid when dosing pump is operating
Check that the pH BOSS diluted acid drum is not empty.
Check that all suction and output hoses are fitted correctly, with no leakage.
- Check that squeeze tube inside pump is not leaking.
WARNING: IF ANY DILUTED ACID HAS LEAKED OUT OF HOSES, WASH DOWN THE AREA WITH FRESH WATER IMMEDIATELY. TAKE THE LID OFF THE PUMP, REMOVE SQUEEZE TUBE AND WASH OUT WITH FRESH WATER IF SQUEEZE TUBE WAS LEAKING.
Alarm sounds due to pH being too low
Dose Setting is set too high
Reduce the Dose Setting by one level and check in 2 days.
Acid Pump turns, but acid is not flowing.
Leaking or worn squeeze tube and/or rollers.
Tighten Acid Pump fittings further or replace fittings.
Replace squeeze tube and/or rollers as needed (see page 15).
IF YOU NEED TO RETURN YOUR pH BOSS FOR SERVICE OR REPAIRS AT ANY TIME, PLEASE USE THE MANUAL DOSE FUNCTION (PAGE 12) TO DOSE 1 LITRE (1 QUART) OF FRESH WATER THROUGH THE SYSTEM BEFORE SENDING BACK. THIS WILL STOP DILUTED ACID LEAKING FROM THE PUMP DURING TRANSPORT (WHICH WOULD DAMAGE YOUR UNIT OR THE PACKAGING, VOIDING WARRANTY), AND IS ALSO A SAFETY HAZARD FOR OUR TECHNICIANS.
pH BOSS ALERTS AND GENERAL MESSAGES.
Alert Messages

pH reading has exceeded Set Point for more than 4 hours.
• Please refer to page 12 for a complete list of possible causes and remedies when the Alarm message is flashing.
• The pH BOSS will not attempt any further acid addition until the alarm is cleared. Press AUTO / OFF to clear the alarm after rectifying the issue.

pH reading is above pH12 or below pH2.
•This alert is displayed immediately if the pH reading goes outside the range of pH2 to pH12. A beeper also sounds. This alert can only be cleared when the pH returns to normal range.
• Check the actual pH of the pool with an independent test.
•Attempt to calibrate the pH BOSS (see pages 13 and 14).
• If calibration fails and the issue persists, the pH probe may require replacement. This can be ordered online at bionizer.com.au.
Reminder Messages

• This reminder is displayed 6 months after the last valid pH Calibration.
• Calibrate the pH Probe as per pages 13 and 14.

• This reminder is displayed when the peristaltic dosing pump has exceeded 50 hours of operation since the last time the Squeeze Tube was lubricated or changed.
• Lubricate or change the Squeeze Tube as per page 15.
General Messages

• This message is displayed each time the pH BOSS is switched on.
• If you need to contact Bionizer for technical support, we may ask you
the software version number (“v2.8SR” in this example).

• This message is displayed each time the pH BOSS is switched on, after the version screen above.
• On this screen, the accumulated pump Squeeze Tube time, and the number of days since the last pH probe calibration are displayed.
Hardware Messages

• The pH BOSS has not been able to obtain data from the internal clock.
• Switch the pH BOSS off for 5 seconds, then back on again. If the problem persists, return the pH BOSS to Bionizer for repair.

• This message can be error number 1 to 9.
• Switch the pH BOSS off for 5 seconds, then back on again. If the problem persists, return the pH BOSS to Bionizer for repair.
WARRANTY REGISTER
Did you purchase your Bionizer products from a pool shop or was it installed by your pool builder?
If so, then please head to the Bionizer Warranty Registration page. Enter the information for each of your Bionizer units to ensure that you obtain your full 5 year warranty.
If you purchased your Bionizer products from Bionizer directly, your 5 year warranty has been automatically registered for you.